Media 000362999: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000362999
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Rana catesbeina
Side
--
Orientation
--
Short description
HRXCT scan - head
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1123 Cannatella: Rana: Scans of the head of Rana catesbeiana (female) (TNHC 20238) for Dr. David Cannatella of The University of Texas at Austin. Specimen scanned by Matthew Colbert 8 November 2004. 16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.1443 mm), S.O.D. 210 mm, 1400 views, 2 samples per view, inter-slice spacing 2 lines (= 0.1443 mm), field of reconstruction 68 mm (maximum field of view 68.81776 mm), reconstruction offset 3600, reconstruction scale 1760. Acquired with 15 slices per rotation. Drift-removal processing done by Susan Garlock based on correction of raw sinogram data using IDL routine “RK_SinoDeDrift” with parameters “driftlength=21” and “goodfile=121”. Reconstructed with default parameters. Rotation correction processing done by Susan Garlock using IDL routine “DoRotationCorrection”. Total slices = 480.
Creator
--
Date created
November 08, 2004
Date uploaded
May 10, 2021

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
1.19 GB
Image width
1010
Image height
836
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.066400
Y pixel spacing
0.066400
Z pixel spacing
0.144300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
480

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Natural History Collections
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334952, DBI-1902242
Publisher
oUTCT PEN
Cite as
David Cannatella provided access to these data, with data collection funded by NSF EF-0334952 and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object TNHC:Herpetology:20238 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
November 08, 2004
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
1400
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000362999: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
May 10, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000362999: Head [CTImageSeries] [CT] (this media)