Media 000364425: Head
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000364425
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Polychrus marmoratus
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 20, 2021

FILE OBJECT DETAILS Field Definitions

File name
UF-H-65135-head.zip
File format(s)
ZIP archive, TIFF
File size
1.72 GB
Image width
1252
Image height
803
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.031768
Y pixel spacing
0.031768
Z pixel spacing
0.031768
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,109

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:65135 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray and Edward Stanley
Event date
--
Software
Datos X|A
Description
microCT of UF-herp-65135
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
2000
Voltage
80KV
Power
16W
Amperage
200uA
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000364425: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
May 20, 2021
Software
Datos X|R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000364425: Head [CTImageSeries] [CT] (this media)