Media 000483106: Endocast
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000483106
Media type
Mesh
Object element or part
Endocast
Object represented
Object taxonomy
Cebuella pygmaea
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Madlen Lang
Date created
November 20, 2022
Date uploaded
November 20, 2022

FILE OBJECT DETAILS Field Definitions

File name
Cebuella_pygmaea__endocast_.ply
File format(s)
PLY
File size
92.8 MB
Points
1253461
Polygons
2518083
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
20.485, 18.407, 25.381
Centroid coordinates
11.382, 9.993, 19.074
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:MAMM:USNM 337324 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1600
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114318: Skull [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000114318: Skull [CTImageSeries] [Etc] was processed to create derived Media 000483106: Endocast [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Madlen Lang
Event date
--
Software
Avizo
Description
Endocast
Description attachment
None

Media produced by this event on MorphoSource

Media 000483106: Endocast [Mesh] [CT] (this media)