Media 000010359: M/1 M/2
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000010359
Media type
Mesh
Object element or part
M/1-M/2
Object represented
Object taxonomy
Macrocranion junnei
Side
Left
Orientation
--
Short description
raw surface file
Full description
Migrated MorphoSource 1 Media File Title: raw surface file Migrated MorphoSource 1 Media Group Title: M/1-M/2
Creator
--
Date created
--
Date uploaded
March 18, 2016

FILE OBJECT DETAILS Field Definitions

File name
UCMP214919-M_1_2_jaw_raw_mirrored.ply
File format(s)
PLY
File size
58.3 MB
Points
1607663
Polygons
3215314
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.941, 3.124, 1.482
Centroid coordinates
-2.167, 2.044, 0.748
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
University of California Museum of Paleontology; University of California Regents
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DGE 1315138
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: N.S. Vitek provided access to these dataoriginally appearing in Vitek et al. 2017 , the collection of which was funded by NSF DGE 1315138. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:214919 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
2
Projections
1500
Voltage
125
Power
0.0050999999999999995
Amperage
41
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000008820: M/1 M/2 [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000008820: M/1 M/2 [CTImageSeries] [Etc] was processed to create derived Media 000010359: M/1 M/2 [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000010359: M/1 M/2 [Mesh] [Etc] (this media)