Media 000113796: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000113796
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Canis lupus
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0241\\r\\n\\r\\nOwen: \\r\\n Scans of Canis lupus (TMM M-1701, Female, Minnesota, Koochiching County, coll. Robert Himes, Winter 1959) for Pamela Owen and Timothy Rowe of the University of Texas, Dept. Geological Sciences. Scanned by Matthew Colbert on May, 11, 2000.\\r\\n\\r\\nlupus: RLS, 420 kV, 1.8 mA, no filter, empty mount wedge, offset 190%, integration time 32 ms, slice thickness 0.5 mm, S.O.D. 730 mm, 1000 views, 4 rays averaged per view, 1 sample per view, inter-slice spacing 0.5 mm, field of reconstruction 145 mm, reconstruction offset 480, reconstruction scale 415.\\n\\nRelated URL: http://digimorph.org/specimens/Canis_lupus_lycaon/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Canis_lupus_lycaon/
Creator
--
Date created
--
Date uploaded
March 27, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
97.2 MB
Image width
508
Image height
446
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.280000
Y pixel spacing
0.280000
Z pixel spacing
0.500000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
457

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Tim Rowe provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:1709 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1000
Voltage
420
Power
--
Amperage
1800
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000113796: Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000113796: Skull [CTImageSeries] [Etc] (this media)