Media 000115578: Skull
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000115578
Media type
Mesh
Object element or part
Skull
Object represented
Object taxonomy
Pseudoeurycea lineola
Side
--
Orientation
--
Short description
3D Mesh of Skull
Full description
Migrated MorphoSource 1 Media File Title: 3D Mesh of Skull Migrated MorphoSource 1 Media Group Title: whole body scan Migrated MorphoSource 1 Media File Description: Created by Anne-Claire Fabre
Creator
--
Date created
--
Date uploaded
May 04, 2020

FILE OBJECT DETAILS Field Definitions

File name
Pseudoeurycea_lineola_UF_62921_cranium.stl
File format(s)
STL
File size
178 MB
Points
355615
Polygons
710563
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.520, 3.621, 5.123
Centroid coordinates
-0.133, -0.171, -4.403
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:62921 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.500093
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1050
Voltage
70
Power
0.008400000000000001
Amperage
120
Surrounding material
1
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000049703: Element Unspecified [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000049703: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000115578: Skull [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000115578: Skull [Mesh] [Etc] (this media)