Media 000167377: Mandible
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000167377
Media type
Mesh
Object element or part
mandible
Object represented
Object taxonomy
Platychoerops daubrei
Side
Right
Orientation
--
Short description
mesh file
Full description
Migrated MorphoSource 1 Media File Title: mesh file Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack, Smooth Surface Mesh Migrated MorphoSource 1 Media File Description: correct chirality
Creator
--
Date created
--
Date uploaded
November 25, 2020

FILE OBJECT DETAILS Field Definitions

File name
ucmp_v_71477_plat-daub.ply
File format(s)
PLY
File size
18.1 MB
Points
499653
Polygons
999772
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
26.649, 34.124, 75.110
Centroid coordinates
27.704, 35.055, 39.877
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
University of California Museum of Paleontology; University of California Regents
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:71477 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1200
Voltage
170
Power
0.01479
Amperage
87
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived private media that exists on MorphoSource but is inaccessible with current user permissions.

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Private media inaccessible with current permissions

STEP 3: IMAGE PROCESSING

Derived private media was processed to create derived Media 000167377: Mandible [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000167377: Mandible [Mesh] [CT] (this media)