Media 000167398: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000167398: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000167398
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Macropus eugenii
Object organization
Side
--
Orientation
--
Short description
--
Full description
University of Texas High-Resolution X-ray CT Facility Archive
Macrini:
Macropus_M1047_: Scan of the skull and mandibles of a Tammar wallaby (Macropus eugenii; TMM M-1047) for Ted Macrini of St. Mary’s University. Specimen scanned by Matthew Colbert 6 May 2015.
16bit: Scan parameters: NSI scanner. Feinfocus source, high power, 190 kV, 0.16 mA, aluminum filter, Perkin Elmer detector, 0.25 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 360 mm, source to detector 1316.544 mm, continuous CT scan, 2 frames averaged, 0 skip frames, 1620 projections, 6 gain calibrations, 15 mm calibration phantom, data range [-0.1, 2] (grayscale range adjusted from NSI defaults), beam-hardening correction = 0.05. Voxel size = 0.0623 mm. Total slices = 1875.
Creator
--
Date created
--
Date uploaded
November 25, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bitTIFF.zip
File format(s)
ZIP archive, TIFF
File size
3.03 GB
Image width
1010
Image height
1062
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.062300
Y pixel spacing
0.062300
Z pixel spacing
0.062300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,875
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DEB-0309369, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Ted Macrini provided access to these data , with data collection funded by NSF DEB-0309369 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tmm:M-1047
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1620
Voltage
190
Power
--
Amperage
160
Surrounding material
0.25 pF gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000167398: Skull [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000167398: Skull [CTImageSeries] [CT] (this media)