Media 000085996: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000085996
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Eurycea multiplicata
Side
--
Orientation
--
Short description
Eurycea multiplicata (USNM 481114)
Full description
Migrated MorphoSource 1 Media File Title: Eurycea multiplicata (USNM 481114) Migrated MorphoSource 1 Media Group Title: Skull of Eurycea multiplicata (USNM 481114) Migrated MorphoSource 1 Media Group Description: DICOM image stack
Creator
--
Date created
--
Date uploaded
September 06, 2019

FILE OBJECT DETAILS Field Definitions

File name
E_multiplicata_USNM481114.zip
File format(s)
ZIP archive, DICOM
File size
182 MB
Image width
545
Image height
458
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.009640
Y pixel spacing
0.009640
Z pixel spacing
0.009640
Pixel spacing units
Mm
Slice thickness
0.0096400
Number of images in set
953

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Grace Capshaw provided access to these dataoriginally appearing in Capshaw et al 2019 with funding provided by NIDCD/NIH T32 DC-000046 to the University of Maryland's Center for Comparative and Evolutionary Biology of Hearing, and by DC-000436 to C.E. Carr. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:HERP:USNM 481114 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Jessica Maisano, Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
120
Power
0.020399999999999998
Amperage
170
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000085996: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Jessica Maisano, Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000085996: Element Unspecified [CTImageSeries] [Etc] (this media)