Media 000098604: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000098604
Media type
Volumetric Image Series
Object element or part
head
Object taxonomy
Sonora semiannulata
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1136\\r\\n\\r\\nMaisano:\\r\\n\\r\\nSonora: Scans of the head of Sonora semiannulata (FMNH 26876) for Dr. Jessie Maisano of The University of Texas at Austin and ATOL. Specimen scanned by Richard Ketcham 9 December 2004. \\r\\n\\r\\n16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.02078 mm), S.O.D. 30.3 mm, 2000 views, 2 samples per view, inter-slice spacing 2 lines (= 0.02078 mm), field of reconstruction 9 mm (maximum field of view 9.92 mm), reconstruction offset 8600, reconstruction scale 1600. Acquired with 15 slices per rotation. Drift- and ring-removal processing done by Susan Garlock based on correction of raw sinogram data using IDL routines “RK_SinoDeDrift” with parameter “driftlength=21” and “RK_SinoRingProcSimul”, with parameter “binwidth=21”. Reconstructed with C-ray offsets between -0.5 and -1.5, using a parameter file. Rotation correction processing done by Susan Garlock using IDL routine “DoRotationCorrection” and images rotated upright using Photoshop. Original image #16 deleted as it was a duplicate. Total final slices = 614.\\r\\n
Creator
--
Date created
--
Date uploaded
January 12, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
607 MB
Image width
791
Image height
747
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.008790
Y pixel spacing
0.008790
Z pixel spacing
0.020780
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
614

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
The Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334961, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these dataoriginally appearing in Gauthier et al., 2012, with data collection funded by NSF EF-0334961 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Amphibians and Reptiles:26876 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
2000
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098604: Head [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000098604: Head [CTImageSeries] [Etc] (this media)