Media 000083182: Humerus
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000083182
Media type
Volumetric Image Series
Object element or part
Humerus
Object represented
Object taxonomy
Terrapene carolina carolina
Object organization
Side
Unknown
Orientation
--
Short description
zipped 16 bit tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped 16 bit tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
July 17, 2019

FILE OBJECT DETAILS Field Definitions

File name
MCZ-R56039_T_carolina_carolina_rec.zip
File format(s)
ZIP archive, TIFF
File size
3.06 GB
Image width
1124
Image height
1124
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.019936
Y pixel spacing
0.019936
Z pixel spacing
0.019936
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,895

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
MCZ Vertebrate Paleontology Collection
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Herp:R-56039 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Blake Dickson
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.8
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
5
Projections
480
Voltage
80
Power
0.008
Amperage
100
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000083182: Humerus [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Blake Dickson
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000083182: Humerus [CTImageSeries] [Etc] (this media)