Media 000052806: Pelvis
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000052806: Pelvis
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000052806
Media type
Mesh
Object element or part
pelvis
Object represented
Object taxonomy
Acrobates pygmaeus
Object organization
Side
--
Orientation
--
Short description
3D mesh
Full description
Migrated MorphoSource 1 Media File Title: 3D mesh Migrated MorphoSource 1 Media Group Title: Micro-CT volume and derivative mesh files
Creator
--
Date created
--
Date uploaded
June 29, 2018
FILE OBJECT DETAILS Field Definitions
File name
Acrobates-pygmaeus-NMHUK-82.7.29.23-pelvis.ply
File format(s)
PLY
File size
26.5 MB
Points
370469
Polygons
742154
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.832, 13.160, 10.159
Centroid coordinates
36.213, 15.206, 41.169
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Natural History Museum, London
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Natural History Museum, London provided access to these dataoriginally appearing in Marin-Serra A, Benson RBJ. 2020. Developmental constraints do not influence long-term phenotypic evolution of marsupial forelimbs as revealed by interspecific disparity and integration patterns. American Naturalist 195(3) , the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
NHMUK:ZOO:ZD 1882.7.29.23
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
Roger Benson, Tom Davies
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2001
Voltage
115
Power
--
Amperage
260
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000052800: Element Unspecified [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Roger Benson, Tom Davies
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000052800: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000052806: Pelvis [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Roger Benson, Tom Davies
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000052806: Pelvis [Mesh] [Etc] (this media)