Media 000007541: Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000007541
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Alouatta palliata
Side
NotApplicable
Orientation
--
Short description
zipped tiff stack of coronal microCT slices
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack of coronal microCT slices Migrated MorphoSource 1 Media Group Title: zipped tiff stack of coronal microCT slices Migrated MorphoSource 1 Media Group Description: fractured cranial vault
Creator
--
Date created
--
Date uploaded
October 21, 2015

FILE OBJECT DETAILS Field Definitions

File name
Alouatta_BAA07_skull_Zstack.zip
File format(s)
ZIP archive, TIFF
File size
831 MB
Image width
1314
Image height
1656
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.055689
Y pixel spacing
0.055689
Z pixel spacing
0.055689
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,876

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
K.L. Allen
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: K.L. Allen provided access to these dataoriginally appearing in Allen Ph.D. dissertation NSF DDIG and the Leakey Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:LP07 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2800
Voltage
205
Power
--
Amperage
175
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000007541: Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000007541: Skull [CTImageSeries] [Etc] (this media)